Products

View our ISO 90001/2008 Certficate  

Single Pair Thermocouple Cables

High Temperature Fibreglass Insulated Flat Twin with Stainless Steel Braid

  • Excellent for high temperature applications up to 480°C for Fibreglass, 800°C for High Temperature Fibreglass and 1400°C for Ceramic Fibre
  • Suitable for use at normal air ambient temperatures where there is a possibility of a hot spot which might damage lower rated cables such as PVC or PFA
  • We offer a wide variety of constructions from simple lapped and Fibreglass braided to stainless steel braided types in virtually all the thermocouple combinations
High Temperature Fibreglass Flat
Twin with Stainless Steel Braid 

One pair of solid conductors. Cores double HT glass fibre lapped, braided and silicone varnished. Pair laid flat, HT glass fibre braided & silicone varnished. Stainless steel wire braided overall.

High Temperature Fibreglass Flat
Twin with Stainless Steel Braid 

One pair of stranded conductors. Cores double HT glass fibre lapped, braided and silicone varnished. Pair laid flat, HT glass fibre braided & silicone varnished. Stainless steel wire braided overall.

Stock Number C78 C79 C71 C80
Number of Strands   1 1 1 13
Size of Strand Diameter (mm)   .5 .8 1.29 .2
Total Area (mm2)   .2 .5 1.3 .44
Approx. Gauge SWG   25 21 18 36
AWG   24 20 16 32
Insulation   High Temp Fibreglass High Temp Fibreglass
Number of Pairs   1 1
Laid Flat or Twisted   Laid Flat Laid Flat
Screen   Yes Yes
Insulation   High Temp Fibreglass High Temp Fibreglass
Insulation
Rating (ºC)
Continuous   +800 +800
Short Term  
Colour Coding   Yes Yes
Physical
Properties
Abrasion Resistance   Good Good
Moisture Resistance   Fair Fair
Typical Weight (Kg/100m)
excl reel
  2 3 5 2
Diameter under Armour (mm)  
Diameter over Armour (mm)  
Overall Diameter   3x4 3x4 5x7 3x4
Recommended Cable Gland Ref.   10 10 16 10
Popular Order Codes

C78KX, C78JX, C78NX

C79KX

C70KX, C70TX, C70JX, C70RCA

C80KX

Notes



All dimensions are approximate
Above 180°C the integrity of the cable is maintained to the upper
insulation rating limit provided the cable is not flexed particularly when cold.
Above 180°C the integrity of the cable is
maintained to the upper insulation rating limit provided the cable is not flexed particularly when cold.

Enquiry Form

1. Stock Number


2. Cable Type


3. Colour Code


4. Quantity Required


 in metres

Contact Details


Company Name


Your Name


Title/Dept.


Email


Telephone


Additional Information


If your enquiry is for more than one style of cable, please email us with your requirements or use the box below



Send Enquiry  

We will only use your email address to contact you. We will never give your email address to 3rd parties and we do not sell data on to any other company. We prefer to concentrate on making quality temperature related products.