Need a quote or advice?

Contact one of our experienced engineers

International: +44 1895 252222
Call TC
TC Ltd for Temperature Measurement & Control

Temperature Transmitters for the Petrochemical, Oil and Gas Industries

IECEx Approved Thermocouple and RTD Transmitter - Head Mounting

Technical Features – Input
Input RTD : Pt100
Input T/C : K, J, T, E, N
Minimum Span See table below

Technical Features – Output/Power Supply
Output : 4..20 mA or 20..4 mA
Linearization : On / Off
Supply : 10..40 VDC, Polarity Protected
Supply Effect : 0.001%/V
Other Features
Max. Ripple :10 V PP. Min Vbat=10 VDC
Zero Drift : ± 0.01%/°C or ±0.02°C/°C
Span Drift : ± 0.005%/°C or ±0.01°C/°C
Long Term Drift : ± 0.05%/Year
Cold Junction Drift : ± 0.01°C/°C
Excitation Current, RTD : 0.1 mA
Sensor Lead Resistance, RTD : 500 Ohm max.
Sensor Lead Resistance Effect : 0.001°C/Ohm
Sensor Lead Resistance, T/C : 10,000 Ohm max.
Open Circuit Detection : Upscale / Downscale
Load Capability : Vbat-10V / 20 mA
Startup Time : 20 sec.
Warmup Time : 5 Min.
Isolation : 500 VDC
Ambient Operating Temp. : -40...+ 85°C.
Storage Temperature : -40...+100°C.
Housing Material : Makrolon
Housing Dimension : 22.5 x 75 x 99 mm (0.89” x 2.92” x 3.9”)
Input and Range Table

 
Input
Range °C
Min Span °C
 
Thermocouple
K
-200... 1370 50  
 
J
-150... 1200 50  
 
T
-200... 400 50  
 
E
-270... 1000 50  
  N 0... 1300 50  
         
RTD Pt100 -200... 850
25
 

Quote Request Form

1. Model

2. Quantity Required

3. Sensor Input

4. Range Details

Range Lower


Range Upper


or Supply unranged?  

Contact Details

Company Name


Your Name


Title/Dept.


Email


Telephone


Additional Information

If your enquiry is for more than one type of transmitter, please email us with your requirements or use the box below